POWERFLUSHING FOR CENTRAL HEATING SYSTEMS

Powerflushing will clean a central heating system internally improving radiator performance and heat output. It can solve all the following problems: Boiler Failure Cause: Assuming no other central heating faults exist, accumulated deposits of sludge and limescale can restrict the transfer of heat to such an extent that the boiler overheats and fractures.
Fuel Wastage Cause: In untreated heating systems, corrosion debris accumulates in the boiler and, in hard water areas limescale will form. The insulating effect of these deposits reduces heat transfer to the circulating water. 3mm of limescale deposit on the heat exchanger will add 18% to your heating fuel bill.
Pump Seizure & FailureCause: Black Oxide sludge, being abrasive and magnetisable, increases shaft and bearing wear which is the most common cause of sticking pumps and pump failures.
Cold Radiators Cause: Sediment of iron oxide sludge accumulating at the bottom of radiators restricts the flow pattern.
Frequent Venting, Cold Spots Near Top of the RadiatorCause: Hydrogen, sometimes mistaken for air, is a by-product of electrolytic corrosion. It is flammable and can be identified easily.
Sludge and ScaleCause: Black Oxide sludge forms continuously in all unprotected central heating systems as a result of corrosion. It will also harden into scale on the hottest surfaces of a system. (i.e. the boiler heat exchanger)


ALL OF THE ABOVE PROBLEMS CAN BE EASILY SOLVED BY POWERFLUSHING YOUR SYSTEM

Description of the Power-flushing process:
1. Remove pump and isolate expansion tank
2. Connect power flush machine to pump position
3. Initial flush of system
4. Add deposit remover
5. Circulate deposit remover
6. Close off all rads except one and circulate through 1 radiator
7. Dislodge deposits by regularly reversing chemical flow to each radiator
8. Repeat steps 6 and 7 for each remaining radiator
9. Dispose deposit remover to waste via machine
10. Connect mains supply to radiator circuits high pressure flush system
11. Dump flushed water to waste via power flush machine until clear
12. Remove power-flushing equipment and reinstate expansion tank & pump
13. Add rust inhibitor and balance system.


Cures flow and circulation problems.
Restores system efficiency.
Restores heat output to radiators.
Cleans the whole system, including under floor pipe work.
Increases pump life, pumping clear water instead of magnetic sludge. Stops hydrogen gases building up which then cause radiator corrosion. Cures or prevents boiler noise.
Power flushing and descaling in only one visit.
Complete process carried out in less than five hours (depending on system size).
More effective than traditional flushing methods.
Minimises boiler warranty problems. Can make your heating system up to 25% more efficient so decreasing fuel costs.